TRANSMITTER PRESSURE:GAUGE 145 TO 7200PSI FOUNDATION FIELDBUS PROTOCOL OUTPUT 1/2IN FNPT +/- 0.04PCT 10.5 TO 32VDC DIGITAL NEMA 4X BRACKET 2IN PIPE IP66/67 HASTELLOY C276 316L SST ASTM CF-8M SS HOUSING M20 FEMALE TWO ELE...
SWITCH PRESSURE:SGL 125/250/480V 15A 1 TO 20IN WC SPDT DIE CAST ALUM ENCLOSURE WELDED 316L SS DIAPHRAGM 1/2IN FNPT 0.72IN ORIFICE NACE MR-0175 W/ INTERNAL ADJUSTMENT DUAL CONDUIT
SWITCH PRESSURE:DIFFERENTIAL 0 TO 40PSID +/-1PCT FULL SCALE SPDT DIE CAST ALUM ENCLOSURE WELDED 316 SS NO-NC -40 TO 160DEG F UL/CUL 1/2IN NPT EPOXY POWDER COATED
GAUGE LEVEL:WELD-ON 333MM LG BODY TOUGHENED GLASS FLG BS3463
TRANSMITTER TEMPERATURE:DIN A HEAD MOUNT FOUNDATION FIELDBUS DIGITAL OUTPUT SINGLE SENSOR INPUT 9 TO 32VDC 12MA LCD DIN A HEAD MOUNT ATEX INTRINSIC SAFETY SENSOR SPECIFIED SEPARATELY AND ASSEMBLED TO TRANSMITTER 60HZ LIN...
TRANSMITTER TEMPERATURE:4 TO 20MA DIGITAL HART OUTPUT SINGLE SENSOR INPUT LCD DISPLAY SS FIELD MOUNT HOUSING ATEX INTRINSIC SAFETY DUAL COMPARTMENT HOUSING M20 X 1.5MM CONDUIT ENTRY INTEGRAL TRANSIENT PROTECTOR CALIBRATI...
TRANSMITTER TEMPERATURE:4 TO 20MA DIGITAL HART OUTPUT SGL SENSOR INPUT SS FIELD MOUNT HOUSING ATEX INTRINSIC SAFETY DUAL COMEPARTMENT HOUSING M20 X 1.5MM CONDUIT ENTRY 50HZ LINE VOLTAGE FILTER CALIBRATION CERTIFICATE
TRANSMITTER TEMPERATURE:4 TO 20MA DIGITAL HART OUTPUT SGL SENSOR INPUT LCD DISPLAY SS FIELD MOUNT HOUSING CALIBRATION CERTIFICATE DUAL COMPARTMENT HOUSING 1/2IN-14NPT CONDUIT ENTRY 50HZ LINE VOLTAGE FILTER
TRANSMITTER DIFFERENTIAL PRESSURE:SCALABLE COPLANAR -300 TO 300PSI FOUNDATION FIELDBUS PROTOCOL OUTPUT 9 TO 32VDC CLASSIC 0.055PCT SPAN ACCURACY SS HOUSING ALLOY C-276 DIAPHRAGM DIN COMPLAINT TRADITIONAL FLG 1/4IN-18NPT...
TRANSMITTER DIFFERENTIAL PRESSURE:SCALABLE COPLANAR -300 TO 300PSI FOUNDATION FIELDBUS PROTOCOL OUTPUT 9 TO 32VDC CLASSIC 0.055PCT SPAN ACCURACY ALUM HOUSING ALLOY C-276 DIAPHRAGM DIN COMPLAINT TRADITIONLA FLG 1/4IN-18NP...
TRANSMITTER DIFFERENTIAL PRESSURE:SCALABLE COPLANAR -1000 TO 1000IN WC FOUNDATION FIELDBUS PROTOCOL OUTPUT 9 TO 32VDC CLASSIC 0.055PCT SPAN ACCURACY SS HOUSING ALLOY C-276 DIAPHRAGM 305 INTEGRAL MANIFOLD PLANTWEB HOUSING...
TRANSMITTER DIFFERENTIAL PRESSURE:SCALABLE COPLANAR -1000 TO 1000IN WC FOUNDATION FIELDBUS PROTOCOL OUTPUT 9 TO 32VDC CLASSIC 0.055PCT SPAN ACCURACY ALUM HOUSING 316L SS DIAPHRAGM 305 INTEGRAL MANIFOLD PLANTWEB HOUSING M...